Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.440
Filter
1.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1551332

ABSTRACT

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Subject(s)
Dental Implants , Dental Prosthesis , Finite Element Analysis , Biomechanical Phenomena
2.
Audiol., Commun. res ; 29: e2778, 2024. tab, graf
Article in Portuguese | LILACS | ID: biblio-1533839

ABSTRACT

RESUMO Objetivo Avaliar a contribuição da tecnologia de escuta assistida em usuários de implante coclear (IC) em situações de reverberação e ruído. Métodos Estudo transversal prospectivo aprovado pelo Comitê de Ética Institucional (CAAE 8 3031418.4.0000.0068). Foram selecionados adolescentes e adultos usuários de IC com surdez pré ou pós-lingual. Para usuários bilaterais, cada orelha foi avaliada separadamente. O reconhecimento de fala foi avaliado por meio de listas gravadas de palavras dissílabas apresentadas a 65 dBA a 0° azimute com e sem o Mini Microfone2 (Cochlear™) conectado ao processador de fala Nucleus®6. A reverberação da sala foi medida como 550 ms. Para avaliar a contribuição do dispositivo de escuta assistida (DEA) em ambiente reverberante, o reconhecimento de fala foi avaliado no silêncio. Para avaliar a contribuição do DEA em reverberação e ruído, o reconhecimento de fala foi apresentado a 0° azimute com o ruído proveniente de 8 alto-falantes dispostos simetricamente a 2 metros de distância do centro com ruído de múltiplos falantes usando relação sinal-ruído de +10dB. Para evitar viés de aprendizado ou fadiga, a ordem dos testes foi randomizada. A comparação das médias foi analisada pelo teste t para amostras pareadas, adotando-se nível de significância de p<0,005. Resultados Dezessete pacientes com idade média de 40 anos foram convidados e concordaram em participar, sendo 2 participantes bilaterais, totalizando 19 orelhas. Houve contribuição positiva significante do Mini Mic2 na reverberação e ruído+reverberação (p<0,001). Conclusão DEA foi capaz de melhorar o reconhecimento de fala de usuários de IC tanto em situações de reverberação quanto ruidosas.


ABSTRACT Purpose This study aimed to evaluate the contribution of assistive listening technology with wireless connectivity in cochlear implant (CI) users in reverberating and noise situations. Methods Prospective cross-sectional study approved by the Institutional Ethics Committee (CAAE 8 3031418.4.0000.0068). Adolescents and adults CI users with pre- or post-lingual deafness were selected. For bilateral users, each ear was assessed separately. Speech recognition was assessed using recorded lists of disyllabic words presented at 65 dBA at 0° azimuth with and without the Wireless Mini Microphone 2 (Cochlear™) connected to the Nucleus®6 speech processor. Room reverberation was measured as 550 ms. To assess the contribution of the assistive listening device (ALD) in a reverberating environment, speech recognition was assessed in quiet. To assess the contribution of the ALD in reverberation and noise, speech recognition was presented at 0° azimuth along with the noise coming from 8 loudspeakers symmetrically arranged 2 meters away from the center with multi-talker babble noise using signal to noise ratio of +10dB. To avoid learning bias or fatigue, the order of the tests was randomized. Comparison of means was analyzed by t test for paired samples, adopting significance level of p <0.005. Results Seventeen patients with a mean age of 40 years were invited and agreed to participate, with 2 bilateral participants, totaling 19 ears assessed. There was a significant positive contribution from the Mini Mic2 in reverberation, and noise+reverberation (p <0.001). Conclusion ALD was able to improve speech recognition of CI users in both reverberation and noisy situations.


Subject(s)
Humans , Male , Female , Adult , Self-Help Devices , Noise Measurement , Cochlear Implantation , Deafness , Voice Recognition , Speech Intelligibility , Cross-Sectional Studies
3.
Arq. bras. oftalmol ; 87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

4.
CoDAS ; 36(1): e20220177, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1528447

ABSTRACT

RESUMO Objetivo Desenvolver guia para elaboração de relatórios fonoaudiológicos de crianças implantadas para serem compartilhados entre fonoaudiólogos dos serviços de implante coclear (IC) e reabilitadores. Método O método Delphi foi utilizado para selecionar os itens relevantes e fundamentais que deveriam constar nas duas versões propostas para compor o guia: Guia 1 - Relatórios fonoaudiológicos fornecidos pelo serviço de IC aos reabilitadores, e Guia 2 - Relatórios fonoaudiológicos fornecidos pelos reabilitadores aos serviços de IC. Vinte e um fonoaudiólogos especialistas e com experiência na área de implante coclear e de reabilitação auditiva participaram da discussão e do julgamento dos itens durante as rodadas de seleção. Considerou-se consenso quando o item obteve a concordância igual ou superior a 80% entre os participantes, sendo selecionados para comporem os dois guias. Resultados Após as duas rodadas, 21 itens do Guia 1 obtiveram consenso entre os terapeutas, ou seja, mais de 80% deles concordaram que estes itens deveriam estar presentes no relatório enviado pelo serviço de IC. Para o Guia 2, 22 itens analisados pelos fonoaudiólogos atuantes em serviços de IC setor pós-operatório, foram selecionados na segunda rodada. Conclusão A partir da análise das duas rodadas, foi desenvolvido o "Guia para a elaboração de relatórios fonoaudiológicos: intersecção entre serviço de IC e reabilitadores". Este material pode ser aplicado na rotina de acompanhamento de crianças implantadas, padronizando as informações compartilhadas sobre o dispositivo eletrônico, resultados de avaliações, monitoramento dos resultados e processo terapêutico dessa população.


ABSTRACT Purpose To develop a guide for the preparation of speech-language reports of implanted children to be shared among speech-language pathologists of cochlear implant (CI) services and rehabilitation professionals. Methods The Delphi method was used to select the relevant and fundamental items that should be included in the two versions proposed for the guide: Guide 1 - Speech-language reports provided by the CI services to rehabilitators, and Guide 2 - Speech-language reports provided by the rehabilitators to CI services. Twenty-one speech therapists specialized and with experience in cochlear implants and auditory rehabilitation participated in the discussion and judgment of the items during the selection rounds. Consensus was considered when the item reached agreement equal to or greater than 80% among participants, being selected to compose the two guides. Results After the two rounds, 21 items from Guide 1 reached consensus among therapists, that is, more than 80% of them agreed that these items should be present in the report sent by the CI service. For Guide 2, 22 items analyzed by speech therapists working in CI services in the postoperative sector were selected in the second round. Conclusion Based on the analysis of the two rounds, the "Guide for the preparation of speech-language pathology reports: intersection between CI service and rehabilitators" was developed. This material can be applied in the follow-up of implanted children, standardizing the information shared about the electronic device, evaluation results, monitoring of results and therapeutic process of this population.

5.
São José dos Campos; s.n; 2024. 64 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1537739

ABSTRACT

A interface implante pilar (IAI) por se constituir de duas peças inevitavelmente apresentam micro lacuna (GAP), na qual pode ocorrer infiltração bacteriana, permitindo a penetração de microorganismos que colonizam na parte interna do implante levando ao acúmulo de biofilme e, podendo levar ao desenvolvimento da periimplantite. O desgaste da conexão interna do implante é algo que ocorre com frequência, muitas vezes pela fratura do parafuso e/ou, pela perda da rosca interna do implante. A ausência de informações prévias também pode gerar a necessidade da remoção do implante, devido a estas intercorrências, surge a possibilidade da criação de um novo componente para implantes para possibilitar a reabilitação protética, sem ter que passar por uma nova cirurgia de remoção e instalação do implante. O objetivo do trabalho foi mensurar o nível de afrouxamento do parafuso do pilar protético e do minipilar comparando com novo componente protéticos, na tentativa de simular o comportamento do conjunto implante/pilar/prótese. Foram utilizados vinte implantes de plataforma cone morse (CM) da DSP® com seus respectivos mini pilares, na qual foram distribuídos em 2 grupos(n=10): Grupo 1 - implante CM + mini pilar FlexCone® DSP + coroa simplificada pirâmide invertida carga aplicada 3 mm do centro da coroa. E Grupo 2 - implante CM + mini pilar novo + coroa simplificada pirâmide invertida carga aplicada 3 mm do centro da coroa. Foram realizados ciclagem mecânica com carga 133 N, durante 2x106 ciclos, com frequência 2 Hz e temperatura de 37ºC em ambos grupos. Um torquímetro digital foi usado para medir os valores de torque reverso do parafuso protético da coroa e também do pilar protético, antes e após o carregamento. Os resultados do modelo de regressão demonstraram diferenças estatisticamente significativas em função do envelhecimento comparando os grupos da coroa sobre o pilar protético (p = 0.020) e entre os grupos do pilar sobre o implante (p = 0.048), indicando que após o envelhecimento de 2.000.000 de ciclos ao longo do tempo está associado de maneira significativa a essas variáveis no contexto deste estudo. O segundo objetivo deste estudo foi avaliar in vitro a taxa de infiltração bacteriana através da IAI, entre o novo componente protético e a superfície interna do implante, juntamente foi analisado a permeabilidade do IAI para colonização bacteriana. Um total de oitenta implantes foram testados. As estruturas montadas para grupo 1 foi torqueado com 20 N/cm e do G2 foram torqueados com 45 N, ambos imersos em microtubos contendo 200 µl de saliva humana. Após 14 dias de incubação da amostra de bactéria nos implantes, foi realizada uma análise qPCR (reação da cadeia da polimerase em tempo real). O teste revelou que não houve diferenças estatisticamente significativas no crescimento bacteriana entre os grupos em qualquer um dos pontos temporais analisados. Conclui-se que o novo componente testado apresentou um destoque menor do que comparado ao mini pilar FlexCone DSP® e apresentou infiltração bacteriana no GAP da conexão implante-pilar semelhante comparado ao mini pilar original da empresa (AU)


The abutment implant interface (IAI), as it consists of two pieces, inevitably presents a micro gap (GAP), in which bacterial infiltration can occur, allowing the penetration of microorganisms that colonize in the internal part of the implant, leading to the accumulation of biofilm and, which can lead to development of peri-implantitis. Wear of the implant's internal connection is something that occurs frequently, often due to screw fracture and/or loss of the implant's internal thread. The lack of prior information can also generate the need to remove the implant, due to these complications, the possibility arises of creating a new component for implants to enable prosthetic rehabilitation, without having to undergo a new surgery to remove and install the implant. implant. The objective of the work was to measure the level of screw loosening of the prosthetic abutment and the mini-abutment compared with the new prosthetic component, in an attempt to simulate the behavior of the implant/ abutment/prosthesis set. Twenty DSP® morse cone (CM) platform implants were used with their respective mini pillars, which were distributed into 2 groups (n=10): Group 1 - CM implant + FlexCone® DSP mini pillar + simplified crown inverted pyramid load applied 3 mm from the center of the crown. And Group 2 - CM implant + new mini abutment + simplified crown inverted pyramid load applied 3 mm from the center of the crown. Mechanical cycling was carried out with a load of 133 N, for 2x106 cycles, with a frequency of 2 Hz and a temperature of 37ºC in both groups. A digital torque wrench was used to measure the reverse torque values of the prosthetic crown screw and also the prosthetic abutment, before and after loading. The results of the regression model demonstrated statistically significant differences as a function of aging comparing the crown-on-prosthetic abutment groups (p =0.020) and between the abutment-on-implant groups (p = 0.048), indicating that after aging 2,000 ,000 cycles over time is significantly associated with these variables in the context of this study. The second objective of this study was to evaluate in vitro the rate of bacterial infiltration through the IAI, between the new prosthetic component and the internal surface of the implant, together with the permeability of the IAI for bacterial colonization. A total of eighty implants were tested. The assembled structures for group 1 were torqued with 20 N/cm and G2 were torqued with 45 N, both immersed in microtubes containing 200 µl of human saliva. After 14 days of incubation of the bacteria sample in the implants, a qPCR (real-time polymerase chain reaction) analysis was performed. The test revealed that there were no statistically significant differences in bacterial growth between groups at any of the time points analyzed. It is concluded that the new component tested presented a lower impact compared to the FlexCone DSP® mini abutment and presented bacterial infiltration in the GAP of the implant-abutment connection similar to the company's original mini abutment.(AU)


Subject(s)
Streptococcus mutans , Dental Implants , Peri-Implantitis
6.
Audiol., Commun. res ; 29: e2728, 2024. tab
Article in Portuguese | LILACS | ID: biblio-1533840

ABSTRACT

RESUMO Objetivo Descrever o impacto da judicialização na realização da cirurgia de implante coclear no Sistema Único de Saúde do Brasil, incluindo o serviço público e a saúde suplementar. Métodos Foi realizado um levantamento documental de acórdãos de todos os tribunais nacionais e a jurisprudência dominante, voltados à cirurgia do implante coclear no Sistema Único de Saúde, no período de 2007 a 2019, por meio da Plataforma Jusbrasil, utilizando o termo "implante coclear" para realização da busca. Também foi realizado um levantamento na plataforma DATASUS (Departamento de Informação do Sistema Único de Saúde) sobre quantos procedimentos de implante coclear unilateral e bilateral foram realizados no mesmo período. Resultados De acordo com o DATASUS, no período de 2008 a 2019 foram realizados 8.857 procedimentos de cirurgia de implante coclear pelos entes públicos ou pelas operadoras dos planos de saúde no país. Com relação à judicialização para solicitação da cirurgia do implante coclear, unilateral ou bilateral, foram encontrados 216 processos, representando 2,43% dos casos. Conclusão A judicialização da saúde, quando se considera a cirurgia do implante coclear, tem representado uma parcela mínima dos casos, o que demonstra baixo impacto no orçamento público e não tem expressiva ação na organização do Sistema Único de Saúde.


ABSTRACT Purpose To describe the impact of Judicialization on the performance of Cochlear Implant (CI) surgery in the Brazilian Unified Health System (SUS), including the public service and supplementary health. Methods A documentary survey of judgments of all National Courts and the Dominant Jurisprudence focused on CI surgery in the SUS from 2007 to 2019 was carried out through the Jusbrasil Platform using the term "cochlear implant" to carry out the search. A survey was also carried out on the DATASUS platform on how many uni and bilateral CI procedures were performed in the same period. Results According to DATASUS, from 2008 to 2019, 8,857 CI surgery procedures were performed by Public Entities or Health Plan Operators in the country. With regard to Judicialization, for requesting unilateral or bilateral CI surgery, a total of 216 processes were found, representing a total of 2.43% of Judicialization of Cochlear Implant (CI) surgery. Conclusion In view of the data, it is possible to perceive that the Judicialization of Health when we consider the CI surgery has represented a small portion of the cases, which does not demonstrate a large impact on the public budget and does not have an impact on the organization of the SUS.


Subject(s)
Humans , Unified Health System , Cochlear Implantation/legislation & jurisprudence , Cochlear Implantation/statistics & numerical data , Supplemental Health , Health's Judicialization/statistics & numerical data , Brazil
7.
São José dos Campos; s.n; 2024. 86 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1551231

ABSTRACT

A eficácia dos implantes osseointegrados é amplamente reconhecida na literatura científica. Contudo, infiltrações bacterianas na junção implante-pilar podem desencadear inflamação nos tecidos circundantes, contribuindo para a evolução de condições mais sérias, como a peri-implantite. O objetivo desse estudo foi produzir complexos polieletrólitos (PECs) de quitosana (Q) e xantana (X) em forma de membranas, carregá-las com ativos naturais e sintéticos antimicrobianos, caracterizálas estruturalmente e avaliá-las frente a degradação enzimática, cinética de liberação e ações antimicrobianas com finalidade de aplicação para drug delivery. Membranas de QX a 1% (m/v) foram produzidas em três proporções, totalizando doze grupos experimentais: QX (1:1); QX (1:2), QX (2:1), QX-P (com própolis) (1:1); QX-P (1:2); QX-P (2:1); QX-C (com canela) (1:1); QX-C (1:2); QX-C (2:1) e CLX (com clorexidina 0,2%) (1:1); CLX (1:2); CLX (2:1). Para os estudos de caracterização foram feitas análises da espessura em estado seco; análises morfológicas superficial e transversal em Microscopia Eletrônica de Varredura (MEV); análise estrutural de espectroscopia de infravermelho por transformada de Fourier (FTIR); análise de degradação por perda de massa sob ação da enzima lisozima; e análise da cinética de liberação dos ativos em saliva artificial. Para os testes microbiológicos, análises de verificação de halo de inibição e ação antibiofilme foram feitas contra cepas de Staphylococcus aureus (S. aureus) e Escherichia coli (E. coli). Os resultados demonstraram que a espessura das membranas variou conforme a proporção, sendo que o grupo QX (1:2) apresentou a maior média de 1,022 mm ± 0,2, seguida respectivamente do QX (1:1) com 0,641 mm ± 0,1 e QX (2:1) com 0,249 mm ± 0,1. Nas imagens de MEV é possível observar uma maior presença de fibras, rugosidade e porosidade nos grupos QX (1:2) e QX (1:1) respectivamente, e, no QX (2:1) uma superfície mais lisa, uniforme e fina. No FTIR foram confirmados os picos característicos dos materiais isoladamente, além de observar as ligações iônicas que ocorreram para formação dos PECs. Na análise de degradação, os grupos com ativos naturais adicionados tiveram melhores taxas de sobrevida do que os grupos QX. No teste de liberação, os grupos QX-P tiveram uma cinética mais lenta que os QX-C, cuja liberação acumulada de 100% foi feita em 24 h. Já nos testes do halo inibitório, somente os grupos CLX tiveram ação sobre as duas cepas, e os QX-P tiveram sobre S. aureus. Nas análises antibiofilme, os grupos CLX apresentaram as maiores taxas de redução metabólica nas duas cepas (± 79%); os grupos QX-P apresentaram taxas de redução similares em ambas as cepas, porém com percentual um pouco maior para E. coli (60- 80%) e os grupos QX-C tiveram grande discrepância entre as duas cepas: de 35 a 70% para S. aureus e 14 a 19% para E. coli. Pode-se concluir que, frente as análises feitas, o comportamento do material foi afetado diretamente pelos ativos adicionados a matriz polimérica. As proporções de Q ou X afetaram somente a espessura final. Quanto a aplicação proposta de drug delivery, os dispositivos apresentaram grande potencial, principalmente os grupos CLX e QX-P. (AU)


The effectiveness of osseointegrated implants is widely recognized in scientific literature. However, bacterial infiltrations at the implant-abutment interface may trigger inflammation in surrounding tissues, contributing to the development of more serious conditions, such as peri-implantitis. The aim of this study was to produce chitosan (Q) and xanthan (X) polyelectrolyte complexes (PECs) in the form of membranes, load and evaluate them for enzymatic degradation, release kinetics, and antimicrobial actions for drug delivery applications. QX membranes at 1% (w/v) were produced in three proportions, totaling twelve experimental groups: QX (1:1), QX (1:2), QX (2:1), QX-P (with propolis) (1:1), QX-P (1:2), QX-P (2:1), QX-C (with cinnamon) (1:1), QX-C (1:2), QX-C (2:1), and CLX (with 0.2% chlorhexidine) (1:1), CLX (1:2), CLX (2:1). Characterization studies included analyses of dry state thickness, surface and crosssectional morphology using Scanning Electron Microscopy (SEM), structural analysis by Fourier Transform Infrared (FTIR) spectroscopy, mass loss degradation analysis under lysozyme action, and active release kinetics analysis in artificial saliva. Microbiological tests included verification analyses of inhibition halos and antibiofilm action against strains of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli). Results showed that membrane thickness varied according to proportion, with group QX (1:2) presenting the highest average of 1.022 mm ± 0.2, followed by QX (1:1) with 0.641 mm ± 0.1, and QX (2:1) with 0.249 mm ± 0.1. SEM images showed greater presence of fibers, roughness, and porosity in groups QX (1:2) and QX (1:1) respectively, while QX (2:1) exhibited a smoother, more uniform, and thinner surface. FTIR confirmed characteristic peaks of the materials individually, besides showing ionic bonds formed for PECs. Degradation analysis revealed that groups with added natural actives had better survival rates than QX groups. In release tests, QX-P groups exhibited slower kinetics than QX-C, with 100% cumulative release achieved in 24 h. inhibitory halo tests, only CLX groups exhibited action against both strains, while QX-P acted against S. aureus. Antibiofilm analyses showed CLX groups with the highest metabolic reduction rates in both strains (± 79%); QX-P groups showed similar reduction rates in both strains, slightly higher for E. coli (60-80%), and QX-C groups had a significant discrepancy between strains: 35-70% for S. aureus and 14-19% for E. coli. In conclusion, material behavior was directly affected by added actives to the polymeric matrix. Proportions of Q or X only affected final thickness. Regarding proposed drug delivery applications, the devices showed great potential, especially CLX and QX-P groups.(AU)


Subject(s)
Drug Delivery Systems , Chitosan , Dental Implant-Abutment Design , Phytochemicals , Polyelectrolytes
8.
Article in English | LILACS-Express | LILACS | ID: biblio-1535330

ABSTRACT

Objective: The aim of this study was to identify if cochlear implant (CI) users are perceiving a decrease in life quality due to voice problems. This study evaluated 43 CI user's perception of their voice and how it affects their quality of life through a survey. Approach: Forty-three CI users responded to a survey regarding their demographics, details about their CI, the Hearing Health Quick Test (HHQT), the Voice Related Quality of Life (V-RQOL), and the Voice Handicap Index-10 (VHI-10). The survey responses were analyzed using univariate linear regression analysis. Results: Few of the CI users scored below the cut off for normal voice related quality of life. CI users averaged 93.4 out of 100 on the V-RQOL and only four scored abnormally for the VHI-10. Lower scores on the V-RQOL were correlated with the participants having an associate degree and with participants visiting friends, family, and neighbors less often due to hearing loss. The VHI-10 scores were correlated with gender, education levels, difficulty in social situations due to hearing loss, noise exposure, and tinnitus. Limitations of the study: The small n was the primary limitation of this study. Originality: This study was one of the first to examine the voice-related quality of life in CI users. Conclusions: Overall, respondents did not perceive much voice-related difficulty. However, they were more likely to perceive voice-related difficulty if they experienced difficulty hearing in noise and avoided social situations due to hearing loss.


Objetivo: Este estudio identificó si los usuarios de implantes cocleares (IC) están percibiendo una disminución en la calidad de su vida debido a problemas de voz. Además, evaluó la percepción de la voz de 43 usuarios de IC y cómo afecta su calidad de vida a través de una encuesta. Enfoque: Cuarenta y tres usuarios de IC respondieron a una encuesta sobre su demografía, detalles sobre su IC, la Hearing Health Quick Test (HHQT), la Voice Related Quality of Life (V-RQOL) y el Voice Handicap Index-10 (VHI-10). Las respuestas de la encuesta se analizaron mediante un análisis de regresión lineal univariado. Resultados: Pocos usuarios de IC puntuaron por debajo del límite para calidad de vida relacionada con la voz. El promedio V-RQOL fue de 93,4/100; solo 4 participantes tuvieron puntuación anormal en VHI-10. Las bajas puntuaciones en V-RQOL se correlacionaron con título de asociado y menos visitas por pérdida auditiva; las puntuaciones VHI-10, con sexo, educación, dificultad en situaciones sociales, exposición al ruido y tinnitus. Limitaciones del estudio: La pequeña n fue la principal limitación de este estudio. Originalidad: Este estudio fue uno de los primeros en examinar la calidad de vida relacionada con la voz en usuarios de CI. Conclusiones: En general, los encuestados no percibieron mucha dificultad relacionada con la voz. Sin embargo, era más probable que percibieran dificultades relacionadas con la voz si tenían dificultades para oír en ruido y evitaban situaciones sociales debido a la pérdida auditiva.

9.
Rev. bras. cir. plást ; 38(4): 1-8, out.dez.2023. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1525493

ABSTRACT

Introdução: Diversos estudos têm analisado a possível relação entre a prótese mamária de silicone e sintomas sistêmicos. A remoção das próteses de mama com capsulectomia tem sido indicada na tentativa de melhorar esses sintomas. É necessário que o cirurgião tenha dados embasados na literatura para informar ao paciente se há relação entre retirada de prótese de mama com capsulectomia e melhora dos sintomas, qual a taxa de melhora e por quanto tempo se mantém. Método: Foi realizada pesquisa nos bancos de dados virtuais Cochrane Library e PubMed de janeiro de 1990 até abril de 2023. A busca foi realizada pela combinação de termos livres ("breast implant illness", "breast capsulectomy" e "breast implant explantation") e pelo uso de operadores booleanos para descritores Mesh como [autoimmune diseases (MeSH Terms)] e [breast implant (MeSH Terms)]. Resultados: Foram obtidos 1.203 artigos, sendo 14 selecionados para o estudo, consistindo em 7 artigos de coorte retrospectivo, 3 de coorte prospectivo e 4 caso-controle. A taxa de melhora variou entre 50 e 100% dos casos e o tempo de acompanhamento variou entre 2 meses e 2,7 anos. Diversos tipos de capsulectomia foram realizados nos estudos, com taxas semelhantes de melhora. Conclusão: Há evidências de melhora dos sintomas sistêmicos em pacientes com prótese mamária de silicone submetidas a retirada de prótese de mama com capsulectomia. A melhora dos sintomas persistiu durante o período em que as pacientes foram acompanhadas nos estudos. Estudos mais recentes demonstraram que o tipo de capsulectomia não tem influência na melhora dos sintomas sistêmicos.


Introduction: Several studies have analyzed the possible relationship between silicone breast implants and systemic symptoms. Removal of breast implants with capsulectomy has been indicated in an attempt to improve these symptoms. The surgeon must have data based on the literature to inform the patient whether there is a relationship between the removal of a breast prosthesis with capsulectomy and improvement in symptoms, what is the rate of improvement, and how long it lasts. Method: A search was carried out in the Cochrane Library and PubMed virtual databases from January 1990 to April 2023. The search was carried out using a combination of free terms ("breast implant illness", "breast capsulectomy," and "breast implant explantation") and by using Boolean operators for Mesh descriptors such as [autoimmune diseases (MeSH Terms)] and [breast implant (MeSH Terms)]. Results: 1,203 articles were obtained, 14 of which were selected for the study, consisting of 7 retrospective cohort articles, 3 prospective cohort articles, and 4 case-control articles. The improvement rate varied between 50 and 100% of cases, and the follow-up time varied between 2 months and 2.7 years. Several types of capsulectomies were performed in the studies, with similar rates of improvement. Conclusion: There is evidence of improvement in systemic symptoms in patients with silicone breast implants who underwent breast implant removal with capsulectomy. The improvement in symptoms persisted during the period in which the patients were followed in the studies. More recent studies have demonstrated that the type of capsulectomy does not influence the improvement of systemic symptoms.

10.
Rev. nav. odontol ; 50(2)20232010.
Article in Portuguese, English | LILACS-Express | LILACS | ID: biblio-1518567

ABSTRACT

A utilização da tecnologia CAD/CAM (computer aided design/computer aided manufacturing) e 3D (tridimensional) para reconstruções alveolares na implantodontia permite o planejamento pré-operatório detalhado, o design do resultado desejado do enxerto e a avaliação virtual do resultado em relação à reconstrução protética. Este trabalho objetiva detalhar a técnica cirúrgica de enxerto ósseo sintético confeccionado por meio dessa tecnologia, seguido da instalação de implantes osseointegráveis e reabilitação protética em um defeito ósseo na mandíbula. Paciente masculino, 22 anos, compareceu à clínica por avulsão dos elementos 32, 31, 41 e 42 com significativa perda óssea vertical de rebordo alveolar. Devido à extensa perda óssea, realizou-se enxerto em bloco prototipado impresso. O escaneamento intraoral e os arquivos de imagem gerados foram enviados ao centro de planejamento virtual. Primeiramente, foi realizada a cirurgia para instalação do enxerto em bloco. Após o período de cicatrização, foi realizada cirurgia para instalação de dois implantes osseointegráveis. Esperado o período de três meses a partir da instalação dos implantes, foi realizada a confecção de próteses provisórias fixas sobre implantes a fim de realizar o condicionamento dos tecidos moles peri-implantares e o carregamento progressivo dos implantes. O aumento do rebordo alveolar através do uso de enxerto em bloco impresso personalizado apresentou-se como uma técnica com inúmeras vantagens, por não necessitar de sítio doador, reduzir tempo cirúrgico e apresentar perfeita adaptação do bloco ao defeito ósseo, resultando em menor morbidade pós-operatória. Essa técnica é uma indicação para casos de defeitos ósseos severos, visando a otimizar o resultado e a propiciar menor desconforto ao paciente.


The use of the technology CAD/CAM (computer aided design/computer aided manufacturing) and 3D (three dimensional) to alveolar reconstructions in implant dentistry allows detailed preoperative planning, the design of the desired grafting result, and the virtual evaluation of the result in relation to the prosthetic reconstruction. This paper aims to details the synthetic bone graft made through this technology, followed by the installation of osseointegrated implants and prosthetic rehabilitation in a bone imperfection in the jaw. A 22-year-old man attended the clinic due to a tooth avulsion of the four lower incisors with significant vertical bone loss of alveolar ridge. Because of the extensive bone loss, it was made a prototyped printed block graft. The intraoral scan and the generated image files were sent to the virtual planning center. First, it was necessary a surgery to install the block graft. After the healing process, it was made a surgery to put two osseointegrated implants. Three months later, temporary fixed prostheses on implants were made to conditioning the peri-implant soft tissues and the progressive loading of the implants. The increase of the alveolar ridge using personalized printed block graft was presented as a technique with numerous advantages, since it does not require a donor site, reduces the surgical time and presents perfect adaptation of the block to the bone imperfection, resulting in a less postoperative morbidity. This technique is indicated to cases of severe bone imperfections, aims to optimize results, and provide less discomfort to the patient.

11.
Medisan ; 27(5)oct. 2023. ilus, tab
Article in Spanish | LILACS, CUMED | ID: biblio-1529000

ABSTRACT

Introducción: La región glútea ha sido considerada una de las zonas más observadas tanto en mujeres como en hombres y constituye un ícono representativo de belleza corporal. En los últimos años se ha incrementado el deseo de las féminas de aumentar esta región anatómica con implantes. Objetivo: Determinar los resultados estéticos de la gluteoplastia de aumento con implantes intramusculares. Métodos: Se realizó un estudio prospectivo, longitudinal y descriptivo de 25 mujeres que acudieron a la consulta externa del Servicio de Cirugía Plástica del Hospital Clínico-Quirúrgico Hermanos Ameijeiras, desde agosto de 2016 hasta febrero de 2019, para solicitar el aumento de su región glútea con implantes. Resultados: En la serie predominaron el grupo etario de 31 a 40 años (36,0 %) y el fototipo de piel III (88,0 %); asimismo, solo 6 pacientes presentaron complicaciones (24,0 %), entre las cuales sobresalieron el seroma (20,8 %), la asimetría (12,5 %) y la dehiscencia de la sutura (8,3 %). Se observó un aumento significativo de la proyección glútea después de la intervención (α=0,05) y los resultados fueron buenos en la mayoría de las integrantes de la muestra (84,0 %). Conclusiones: La gluteoplastia de aumento con implantes intramusculares es un procedimiento seguro y ofrece resultados estéticos favorables.


Introduction: Gluteal region has been considered one of the most observed areas either in women as in men and constitutes a representative icon of corporal beauty. In the last years the desire of women to increase this anatomical region with implants has been increased. Objective: To determine the aesthetic results of the augmentation gluteoplasty with intramuscular implants. Methods: A prospective, longitudinal and descriptive study of 25 women that went to the Plastic Surgery Service outpatient consultation of Hermanos Ameijeiras Clinical Surgical Hospital was carried out from August, 2016 to February, 2019, to request the increase of the gluteal region with implants. Results: In the series there was a prevalence of the 31 to 40 age group (36.0%) and the skin phototype III (88.0%); also only 6 patients presented complications (24.0%), among which seroma (20.8%), asymmetry (12.5%) and anastomotic dehiscence (8.3%) were notable. A significant increase of the gluteal projection after the intervention was observed (α =0.05) and the results were good in most of the members of the sample (84.0%). Conclusions: The augmentation gluteoplasty with intramuscular implants is a safe procedure and offers favorable aesthetic results.

12.
Int. j. morphol ; 41(5): 1317-1322, oct. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1521018

ABSTRACT

SUMMARY: Traumatized bone tissue has the capacity to repair itself so that it eventually regains its almost original form, even in the case of artificially inserted implants. The process that stays at the base of the regeneration is represented by osteogenesis or remote osteogenesis. The major difference between the two types of bone formation is the location of the cement line, which is located on the surface of the implant for contact osteogenesis and on the surface of the bone defect for remote osteogenesis. The aim of the present study was to assess the contact osteogenesis in the case of inserted titanium screws in holes with diameters of 1.8 mm and 1 mm respectively. The obtained results show, in the case of the groove with 1.8 mm that the newly proliferated bone represents 73.85 % of the total area, while in the case of the groove with 1 mm in diameter the value of the newly proliferated bone is 26.15 %. In conclusion, the insertion of titanium screws by self-tapping into the hole smaller than the core of the screw is accompanied by bone proliferation by contact osteogenesis much more modest than in the case of insertion into the hole larger than the core of the screw.


El tejido óseo traumatizado tiene la capacidad de reparar en forma espontánea, de modo que eventualmente recupera su forma casi original, incluso en el caso de implantes insertados artificialmente. El proceso que queda en la base de la regeneración está representado por la osteogénesis u osteogénesis a distancia. La principal diferencia entre los dos tipos de formación ósea es la ubicación de la línea de cemento, que se encuentra en la superficie del implante para la osteogénesis de contacto y en la superficie del defecto óseo para la osteogénesis remota. El objetivo del presente estudio fue evaluar la osteogénesis de contacto en el caso de tornillos de titanio insertados en forámenes con diámetros de 1,8 mm y 1 mm respectivamente. Los resultados obtenidos muestran, en el caso del surco de 1,8 mm que el hueso neoproliferado representa el 73,85 % del área total, mientras que en el caso del surco de 1 mm de diámetro el valor del hueso neoproliferado es del 26,15 %. En conclusión, la inserción de tornillos de titanio por autorroscantes en el foramen menor que el núcleo del tornillo se acompaña de una proliferación ósea por osteogénesis de contacto mucho más modesta que en el caso de la inserción en el foramen mayor que el núcleo del tornillo.


Subject(s)
Animals , Male , Rabbits , Osteogenesis , Prostheses and Implants , Titanium/chemistry , Bone Screws , Osseointegration
13.
Rev. chil. nutr ; 50(5)oct. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1530010

ABSTRACT

Objetivo: Analizar el efecto sobre el peso corporal de la anticoncepción hormonal continua mediante implante sub-dérmico liberador de etonogestrel (ENG) en mujeres en edad reproductiva atendidas en la consulta de planificación familiar de un hospital venezolano. Métodos: Investigación comparativa, con diseño cuasi experimental, de casos y controles, a etiqueta abierta, y prospectivo; con una muestra intencionada de 60 mujeres separadas para recibir bien sea un implante subdérmico (Implanon NXT®; casos) o un dispositivo intrauterino (DIU) de cobre (T de cobre; controles). Se evaluaron el peso corporal e índice de masa corporal antes y posterior de doce meses del uso del contraceptivo; así como las características demográficas de las usuarias, efectos adversos y efectividad anticonceptiva de cada método. Resultados: Luego de un año con el implante de ENG no se encontraron variaciones significativas respecto a las mediciones iniciales del peso corporal (61,21±8,30 vs. 61,23±9,50, p>0,5) e IMC (25,23±3.89 vs. 25,26 ±4,30; p>0,05); contrariamente, a lo observado entre las usuarias del DIU donde tanto el peso corporal como el IMC tuvieron un aumento significativo (P<0,05). Asimismo, la mayoría de las usuarias se mantuvieron en el mismo rango de peso donde se encontraban al iniciar el método (p<0,001); mientras que la ganancia ponderal fue mayor entre las usuarias del DIU (1,530±2,04 vs. 3,700±3,02; p<0,05). Conclusiones: El implante de ENG no produce aumento del peso corporal luego de 12 meses de uso, con mínimos efectos adversos y alta efectividad contraceptiva.


Aim: To analyse the effect on body weight of continuous hormonal contraception by releasing subdermal implant etonogestrel (ENG) in women of reproductive age treated in the family planning consultation of a Venezuelan hospital. Methods: Comparative and applied research, with quasiexperimental, case-control, open label and prospective design, with an intentional sample of 60 women separated to receive the contraceptive implant (Implanon NXT®; cases) or a cooper intrauterine device (IUD) (Cooper T; controls) was carried out. Body weight and body mass index were evaluated before and after 12 months of contraceptive use; as well as demographic characteristics of users, side effects, and contraceptive effectiveness of each method. Results: After one year with the ENG implant, no significant variations were found with respect to initial measurements of body weight (61.21±8.30 vs. 61.23±9.50, p>0.5) and BMI (25.23±3.89 vs 25.26±4.30; p>0.05); on the contrary, to what was observed among IUD users where both body weight and BMI had a significant increase (P<0.05). Likewise, most users remained in the same weight range as when starting the method (p<0.001); while weight gain was greater among IUD users (1,530±2.04 vs. 3,700±3.02; p<0.05). Conclusions: The ENG implant does not produce an increase in body weight after 12 months of use, with minimal adverse effects and high contraceptive efficacy.

14.
Rev. ADM ; 80(4): 204-208, jul.-ago. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1526314

ABSTRACT

Objetivo: disminuir el efecto de artefacto que generan objetos de alta densidad mediante la utilización de filtros de distintos materiales y espesores, ubicados en lugares estratégicos del tomógrafo. Material y métodos: se utilizaron filtros de aluminio y de cobre ubicados en lugares estratégicos en el equipo tomográfico. Se realizaron cortes oblicuos en piezas dentarias con restauraciones metálicas y en implantes; se midió la extensión del artefacto en ancho y alto en cada adquisición tomográfica. Resultados: se hallaron diferencias significativas respecto a la disminución de la dispersión de acuerdo con cada filtro con respecto a la no utilización de estos elementos. Conclusión: la utilización de filtros logró disminuir el efecto de artefacto en estructuras de alta densidad, obteniendo una mejor calidad de imagen para el diagnóstico, permitiendo que el software pueda reconstruir una imagen real (AU)


Objective: to diminish the artifact effect generated by high density objects by using filters of different materials and thickness, located in strategic places of the tomograph. Material and methods: aluminum and copper filters located in strategic places in the tomographic equipment were used. Oblique cuts were made on dental pieces with metal restorations and implants; the extension of the artifact in width and height was measured in each tomographic acquisition. Results: significant differences were found regarding the decrease of the dispersion according to each filter with respect to the non-use of these elements. Conclusion: the use of filters achieves to diminish the artifact effect in structures of high density, obtaining a better image quality for the diagnosis, allowing the software to reconstruct a real image (AU)


Subject(s)
Artifacts , Dental Equipment , Cone-Beam Computed Tomography , Dental Implants , Filters , Aluminum
15.
Arq. bras. oftalmol ; 86(4): 301-307, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447364

ABSTRACT

ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.


RESUMO Objetivo: Avaliar os resultados visuais, satisfação e qualidade de vida de pacientes atendidos em um hospital escola pelo Sistema Único de Saúde, submetidos a implante bilateral de lente intraocular multifocal difrativa. Métodos: Estudo tipo série de casos com intervenção, incluindo 20 pacientes submetidos a implante bilateral da lente intraocular multifocal difrativa EyeDiff® (Eyeol UK, Dunstable, UK). Os critérios de exclusão foram astigmatismo corneano >1,5 dioptria cilíndrica, cirurgia ou doença ocular prévias e complicações intraoperatórias ou pós-operatórias. Os pacientes foram avaliados após 1, 3 e 6 meses da cirurgia. Foram avaliadas a acuidade visual monocular e binocular para longe, intermediário e perto sob condições fotópica e mesópica, sensibilidade ao contraste monocular sob condições fotópicas, curva de defocus e questionário para avaliação da qualidade de vida. Resultados: A acuidade visual para longe corrigida monocular foi de 0,3 logMAR ou melhor e a acuidade visual para perto com correção para longe foi J3 ou melhor em todos os olhos, sob condições fotópicas. A acuidade visual binocular para perto com a correção para longe foi J1 em todos os casos. A sensibilidade ao contraste estava no nível mínimo de normalidade para frequências espaciais baixas e altas e abaixo dos limites normais para frequência espacial intermediária. O questionário de qualidade de vida mostrou que os pacientes apresentavam altos níveis de satisfação. Conclusão: O implante bilateral da lente intraocular multifocal EyeDiff® proporcionou boa acuidade visual e qualidade de vida, e independência de óculos aos pacientes. A acuidade visual e a sensibilidade ao contraste melhoraram progressivamente entre um e seis meses de pós-operatório.

16.
Arq. bras. oftalmol ; 86(4): 380-383, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447369

ABSTRACT

ABSTRACT We report two cases of stage 3A unilateral Coats' disease in pediatric patients. In both cases, disease control was achieved using a dexamethasone intravitreal implant in addition to other treatments. The treatment improved visual acuity in one patient and prevented the worsening of the decline in visual acuity in the other patient during follow-up periods of 7 and 3 years, respectively. One of the patients presented an increase in intraocular pressure, which was controlled with topical antiglaucoma medication, but developed a cataract that required surgery. In conclusion, dexamethasone intravitreal implant may be a useful adjuvant treatment to consider in some pediatric cases with Coats' disease.


RESUMO Relatamos dois casos de doença de Coats em estágio 3A unilateral em pacientes pediátricos. Em ambos os casos, o controle da doença foi obtido com implante intravítreo de dexametasona, além de outros tratamentos, com melhora da acuidade visual em um caso e sem piora da visão no outro, durante um período de acompanhamento de 7 e 3 anos. Um dos casos apresentou elevação da pressão intraocular controlada com medicação antiglaucoma tópica e desenvolveu catarata que exigiu cirurgia. Em conclusão, o implante intravítreo de dexametasona pode ser um tratamento adjuvante útil a ser considerado em alguns casos pediátricos com doença de Coats.

17.
Rev. bras. cir. plást ; 38(2): 1-6, abr.jun.2023. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1443493

ABSTRACT

Introduction: The mastopexy with implants and L-shaped scarring aims to correct grades I to II breast ptosis using implants in retroglandular space and retromuscular dual plane space, at the same surgical time. The objective is to describe the experience with the L-augmentation mastopexy technique, analyzing complications and reoperations. Methods: Retrospective study of 123 patients with mild to moderate breast ptosis, operated using the L-augmentation mastopexy technique from January 2011 to November 2021. Results: The mean age of patients was 35.6 years. The average volume of implants used was 315ml (range 175 to 600ml). The placement of the prosthesis was in retroglandular (46.5%) and dual plane retromuscular space (53.5%). The average operative time was two hours and fifty-four minutes. The main complications presented were superficial dehiscence (7.3%), recurrence of ptosis (7.3%) and unsightly scars (5.7%). Surgical reviews took place in 13 patients (10.5%). Conclusion: Safe and effective mastopexy technique with implant in the treatment of mild to moderate breast ptosis, providing well designed breasts with reduced L-shaped scars.


Introdução: A mastopexia com implantes e cicatriz em L visa corrigir ptoses mamárias graus I a II com utilização de implantes em espaço retroglandular e retromuscular dual plane, no mesmo tempo cirúrgico. O objetivo é descrever a experiência com a técnica de mastopexia de aumento em L, analisando complicações e reoperações. Método: Estudo retrospectivo de 123 pacientes com ptose mamária leve a moderada, operadas pela técnica de mastopexia de aumento em L no período de janeiro de 2011 a novembro de 2021. Resultados: A média de idade das pacientes foi de 35,6 anos. O volume médio de implantes utilizado foi de 315ml (variação de 175 a 600ml). O posicionamento da prótese foi em espaço retroglandular (46,5%) e retromuscular dual plane (53,5%). O tempo médio operatório foi de duas horas e cinquenta e quatro minutos. As principais complicações apresentadas foram deiscências superficiais (7,3%), recorrência da ptose (7,3%) e cicatrizes inestéticas (5,7%). Revisões cirúrgicas aconteceram em 13 pacientes (10,5%). Conclusão: Técnica de mastopexia com implante segura e eficaz no tratamento da ptose mamária leve a moderada, proporcionando mamas bem projetadas com cicatrizes reduzidas em L.

18.
Arq. bras. oftalmol ; 86(3): 223-231, May 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439379

ABSTRACT

ABSTRACT Purpose: To compare viscotrabeculotomy with anterior chamber irrigation to Ahmed glaucoma valve implantation for secondary glaucoma following silicone oil removal. Methods: A prospective study was conducted on 43 vitrectomized pseudophakic eyes with persistent glaucoma after silicone oil removal. Patients were randomized to either viscotrabeculotomy with anterior chamber irrigation or Ahmed glaucoma valve implantation. All patients were examined on day 1, week 1, and months 1, 3, 6, 9, 12, 18, and 24 postoperatively. Postoperative complications were noted. Success was defined as an intraocular pressure between 6 and 20 mmHg and with an intraocular pressure reduction of >30% compared with the preoperative intraocular pressure. Results: There were 22 eyes in the viscotrabeculotomy with anterior chamber irrigation and 21 eyes in the Ahmed glaucoma valve implantation group. The mean preoperative and postoperative intraocular pressure in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 35.5 ± 2.6 mmHg and 35.5 ± 2.4 mmHg and 16.9 ± 0.7 mmHg and 17.9 ± 0.9 mmHg respectively (p˂0.0001). There was a statistically significant intraocular pressure reduction at all follow-up time points compared to preoperative values (p˂0.0001) in both groups. The unqualified success rate in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 72.73% and 61.9%, respectively. A minimal self-limited hyphema was the most common complication. Conclusions: Both viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation are effective in lowering the intraocular pressure in glaucoma after silicone oil removal with viscotrabeculotomy with anterior chamber irrigation providing greater reduction, higher success rates, and minimal complications.


RESUMO Objetivo: Comparar a viscotrabeculotomia com irrigação da câmara anterior com o implante de válvula de glaucoma de Ahmed para glaucoma secundário após remoção de óleo de silicone. Métodos: Foi realizado um estudo prospectivo de 43 olhos pseudofácicos vitrectomizados com glaucoma persistente após a remoção de óleo de silicone. Os pacientes foram randomizados para viscotrabeculotomia com irrigação da câmara anterior ou implante de válvula de Ahmed. Todos os pacientes foram examinados no primeiro dia, na primeira semana e 1, 3, 6, 9, 12, 18 e 24 meses após a cirurgia. Observaram-se complicações pós-operatórias. O sucesso foi definido como uma pressão intraocular entre 6 e 20 mmHg e uma redução da pressão intraocular >30% em comparação com a pressão intraocular pré-operatória. Resultados: Foram designados 22 olhos para o grupo da viscotrabeculotomia com irrigação da câmara anterior e 21 olhos para o grupo do implante de válvula de Ahmed. A pressão intraocular média pré-operatória foi de 35,5 ± 2,6 mmHg para o grupo da viscotrabeculotomia com irrigação da câmara anterior e pós- e de 35,5 ± 2,4 mmHg no grupo do implante de válvula de Ahmed. e Os valores pós-ope­ratórios foram de 16,9 ± 0,7 mmHg e 17,9 ± 0,9 mmHg para esses mesmos grupos, respectivamente (p<0,0001). Ambos os grupos tiveram uma redução estatisticamente significativa da pressão intraocular em relação aos valores pré-operatórios (p<0,0001) em todos os momentos do acompanhamento. A taxa de sucesso não qualificado nos grupos da viscotrabeculotomia com irrigação da câmara anterior e do implante de válvula de Ahmed foi de 72,73% e 61,9%, respectivamente. A complicação mais comum foi o hifema, autolimitado e mínimo. Conclusões: Tanto a viscotrabeculotomia com irrigação da câmara anterior quanto o implante de válvula de Ahmed são eficazes na redução da pressão intraocular no glaucoma após injeção de óleo de silicone, mas a viscotrabeculotomia com irrigação em câmara anterior proporcionou maior redução da pressão intraocular e maiores taxas de sucesso, com complicações mínimas.

19.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1440277

ABSTRACT

Objetivo: Esta revisión sistemática tiene como objetivo identificar los factores pronósticos y/o determinantes del éxito del tratamiento de la periimplantitis. Materiales y métodos: Se realizó una búsqueda bibliográfica estructurada y exhaustiva para identificar referencias relevantes en las bases de datos MEDLINE (PubMed), Scielo y Springerlik. La estrategia de búsqueda se realizó combinando los términos periimplantitis con factores pronósticos y / o determinantes del éxito del tratamiento como MeSH y texto libre combinando con los operadores booleanos AND y OR. Se utilizó la clasificación de SIGN (Scottish Intercollegiate Guidelines Network) para analizar el nivel de evidencia. Resultados: De los 239 artículos revisados, 17 cumplieron con los criterios de selección para el análisis cualitativo de la evidencia. Conclusiones: El tipo de implante (macro y microgeometría) y la morfología del defecto, los cuales dificulta el acceso a las superficies contaminadas, son factores que influyen en el resultado del tratamiento de la periimplantitis. No hay evidencia sobre el método de descontaminación más eficaz. Las condiciones generales como la diabetes mellitus y la presencia de enfermedad periodontal activa afectan el resultado del tratamiento, así como la frecuencia de un programa de mantención de higiene profesional postquirúrgica, la cual mejora la sobrevida del implante.


Objective: This systematic review aimed at identifying prognostic factors influencing periimplantitis treatment outcomes. Materials and methods: A structured and comprehensive literature search was performed to identify relevant references from MEDLINE (PubMed), Scielo and Springerlik databases. The search strategy was carried out combining the search terms periimplantitis with prognostic factors and/or determinants of treatment success as MeSH and free text combining with the boolean logical operators AND and OR. The SIGN (Scottish Intercollegiate Guidelines Network) was used to analyze the level of evidence. Results: From 239 articles reviewed, 18 fulfilled the selection criteria for the qualitative analysis of the evidence. Conclusions: The type of implant (macro and microgeometry) and the defect morphology, which make access to contaminated surfaces difficult, are factors that influence the outcome of peri-implantitis treatment. There is no evidence on the most effective decontamination method. General conditions such as diabetes mellitus and the presence of active periodontal disease affect the outcome of the treatment. as Also, the frequency of a post-surgical professional hygiene maintenance program improves the dental implant survival post-treatment.

20.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1440280

ABSTRACT

La ausencia de un diente puede originar sobre-erupción de su antagonista debido al movimiento fisiológico. Distintos métodos se han empleado para lograr la rehabilitación en espacios interoclusales reducidos, la mayoría implica un tallado del diente antagonista o incluso la extracción dental. La intrusión dental periodontalmente asistida (corticotomía), es una alternativa terapéutica en la que el tallado del diente extruido ya no es necesario, conservando su integridad coronaria. Reporte de caso: Paciente femenino de 56 años con ausencia del 4.7, además presenta sobre-erupción del 1.7, limitando el espacio interoclusal y su rehabilitación. Se realizó intrusión del 1.7 mediante corticotomía con el Piezoeléctrico (técnica Piezocision) así como la colocación de minitornillos de ortodoncia para anclaje. Obtenido dicho espacio interoclusal, se rehabilitó con un implante dental. Conclusiones: La intrusión de molares con el apoyo de mini-implantes y corticotomías es un procedimiento que tiene como beneficio la creación de un espacio interoclusal para su restauración en un periodo corto de tiempo, sin tallar la estructura dentaria.


The absence of a tooth can cause over-eruption of its antagonist due to a physiological movement. Different methods have been used to achieve rehabilitation in reduced interocclusal spaces. Most of them involve the wear of the opposing tooth or even dental extraction. Periodontal-assisted dental intrusion is a therapeutic alternative that does not require the reduction of the extruded tooth and preserves its structure. Case report: 56-year-old female patient with absence of tooth 4.7, also presenting an over-eruption of 1.7, limiting the interocclusal space and rehabilitation. Intrusion of tooth 1.7 was performed with corticotomy using the piezocision technique and placement of mini-screws followed by the placement of a dental implant. Conclusions: The intrusion of molars aided by orthodontic mini-screws and piezocision technique is an effective treatment, whose benefit is the creation of an ideal prosthetic space in a short period of time, avoiding the reduction of dental structure.

SELECTION OF CITATIONS
SEARCH DETAIL